connectors, CIR connectors, ITT Interconnect SolutionsHigh temperature CIR connectors from ITT Interconnect SolutionsNews Release from:
ITT Interconnect Solutions High temperature VEAM CIR connectors, described in a new application note from hi-rel connector company, ITT Interconnect Solutions, were developed to address concerns of passenger safety on the European railway system — specifically the new European standards CEN/TS 45545 governing fire railway safety. These regulations require a connector able to withstand high temperature exposure for a period of 15 minutes, where the exposure-criteria are governed by the ISO 834-1 heating curve (maximum temperature of 800degC).
VEAM CIR connectors from ITT Interconnect Solutions are able to withstand well over 15 minutes (handle 30 minutes minimum) of exposure to the ISO 834-1 mandated heating curve. The idea behind these standards and VEAM CIR is to ensure that the connectors remain active while the train moves away from the site of accident or fire. This guarantees that critical control signals remain viable without the need for complex technical solutions. |